| Patient range | Adult, pediatric, neonate |
| NIBP Measurement method | Oscillometric |
| NIBP Measurement range | 0 kPa – 38.67 kPa (0 mmHg – 290 mmHg) |
| NIBP Measurement mode | Arm Measurement |
| NIBP Measurement interval | 15, 30, 60, 120, 240 min (Auto mode ) |
| NIBP - Resolution | 1 mmHg |
| NIBP - Accuracy | ± 3 mmHg |
| Pulse Rate Measurement range | 40 bpm – 240 bpm |
| Pulse rate - Resolution | 1 bpm |
| Pulse rate - Display | 2.4” color TFT – LCD |
| Power Supply | DC : 3 V |
| Alarm | SYS, DIA (User defined) |
| Storage | Auto mode : up to 350 results Manual mode : up to 300 results |
| Dimension | 128 × 69 × 36 mm |
| Weight | < 300 g |
| Display | 12.1” LCD display |
| Ultrasound frequency | 1024 (1 ± 10%) kHz |
| Max output intensity | < 10 MW/cm2 |
| FHR measurement range | 30 bpm ~ 240 bpm |
| FHR sensitivity | ≤ 2 bpm |
| FHR alarm range | 30 bpm ~ 240 bpm |
| Alarm time | ≤ 30s |
| Alarm limits | FHR Higher [User defined] FHR Lower [User defined] TOCO Higher [User defined] TOCO Lower [User defined] |
| TOCO measurement range | 0 ~ 100 units |
| TOCO baseline | 0 ~ 20 units |
| TOCO sensitivity | ≤ 10 % |
| Recorder paper speed | 1,2,3 cm/min |
| Recorder deviation | ≤ 5 % |
| Print duration | 5 min – 240 min |
| Safety standard | Class I, BF type |
| Storage temperature range | 40℃ ~ 55℃ |
| Storage relative humidity | ≤ 93 % |
| Storage pressure range | 500 hPa ~ 1060hPa |
| Operational temperature range | 10°C ~ 40°C |
| Relative humidity | ≤ 80 % |
| Atmosphere pressure | 70 kPa ~ 106 kPa |
| Weight | 4.5 Kgs |
| Display | OLED 160 x 128 dot matrix display |
| Storage | Built-in TF card storage for up to 2 GB |
| Standard Sensitivity | 10 mm/mV ± 5% |
| Sensitivity Shift | ≤ ± 10% |
| Channel Display | 12 Channel |
| Scan Speed | 25 mm/s ± 5% |
| Pacing Analysis | Dual chamber pacing, Atrial pacing, Ventricular pacing module Ventricular Pseudofusion and Ventricular asynchronous module |
| Arrhythmia Analysis | MCSSTM and TMCATM |
| ECG-Analysis | ST segment analysis , HRT analysis, T-Wave alternation,QTD (QT dispersion) VCG (vector cardiogram), VLP (ventricular late potential) and TVCG (time vector cardiogram) analysis |
| Heart-rate Analysis | Short range : 5 minutes Long range : 1 hour Continuous : 24 hours |
| Sampling | Sampling Accuracy : 12 Bit Rate of Sampling : 10 kHz |
| Batteries | 2 AA batteries |
| Interface | USB 2.0 |
| Scale Voltage | 1mV ± 5% |
| Noise | ≤ 30µV |
| CMRR | ≥ 60 dB |
| Time Constant | ≥ 3.2 s |
| Polarization voltage | ± 300 mV (DC) |
| Dimension | 111 x 60 x 25 mm |
| Weight | 105 g |
| Vital Parameters |
|
||||||
| Display | 240 x 320 dot matrix colour TFT | ||||||
| NIBP Measurement range | Adult: 30-255 mmHg Paediatric: 30-160 mmHg | ||||||
| NIBP Mode | Auto, Manual, STAT | ||||||
| NIBP Parameters | SYS, DIA, MAP | ||||||
| NIBP interval | Auto mode: 1, 2 , 3, 5, 10, 15, 20, 25, 30, 45, 60 mins STAT mode: 5 mins | ||||||
| Resolution | 1 mmHg | ||||||
| NIBP Over-pressure protection | Adult: 300 mmHg Pediatric: 22 mmHg | ||||||
| SpO2 Measurement range | 0 - 100% | ||||||
| SpO2 Accuracy | ±2% (90-100)%, ±3% (70-89)%, <70% (unspecified) | ||||||
| SpO2 Resolution | 0.01 | ||||||
| PR Measurement range | 30 bpm - 250 bpm | ||||||
| PR Accuracy | ±1 bpm | ||||||
| PR Resolution | 1bpm | ||||||
| Temp Probe | Body sensitive temperature sensor | ||||||
| Temp Measurement range | 0⁰C to 50⁰C | ||||||
| Temp Accuracy | ± 0.1⁰C | ||||||
| Temp Resolution | 0.1⁰C | ||||||
| Graphic LCD size | 44 x 59 mm | ||||||
| Audio-visual Alarms | Sensor-off alarm, Measurement out of user-defined limits | ||||||
| Data Transmission | USB-based transmission to PC Internet-based tele monitoring | ||||||
| Operational Temperature | 0⁰C to 45⁰C | ||||||
| Relative Humidity | 15% to 95% | ||||||
| Pressure | 86 kPa – 106 kPa | ||||||
| Power Supply | Input power: AC 100-240V, 50-60Hz, 0.7A Output power: 5V,2.5A | ||||||
| Battery | 2.8 A built-in rechargeable Li-ion battery Run Time : 5 hours Charging Time : 8 hours |
| Vital Parameters | 3 Parameters (SpO2 (with PR), NIBP, & 1-channel TEMP) |
| NIBP Measurement range | Systolic Adult 50 ~ 265 mmHg Child 25 ~ 135 mmHg Diastolic Adult 15 ~ 220 mmHg Child 12 ~ 110 mmHg MAP Adult 25 ~ 245 mmHg Child 18 ~ 120 mmHg |
| NIBP Mode | Manual, Auto |
| NIBP Parameters | Sys, Dia, MAP |
| NIBP interval | Auto Mode: 1 ~ 240 min, < 10 s |
| NIBP Over-pressure protection | Adult: 300 mmHg Child: 140 mmHg |
| SpO2 Measurement range | 35 % ~ 100 % |
| SpO2 Accuracy | 75 % ~ 100 % @ ± 2 % 35 % ~ 74 % @ ± 3 % |
| PR Measurement range | 30 bpm ~ 250 bpm |
| PR Accuracy | ±2 bpm |
| TEMP Monitoring range | 21 ⁰C ~ 50 ⁰C |
| TEMP Monitoring accuracy | ±0.1 ⁰C |
| TEMP Responding time | ≤ 150 s |
| Recording speed | 25 mm/s |
| Recording speed accuracy | ≤ 5% |
| Power Supply | AC 100-250V, 50-60Hz |
| Battery | 12 V, 2.3 AH (Lead-acid battery) |
| Standard Parameter | 5‐lead ECG, RESP, HR, NIBP, SpO2(F‐5), 1‐TEMP, PR |
| Patient Groups | Neonate, Pediatric, Adults |
| Trace | 9 waveform (ECG,SpO2, RESP) |
| ECG Lead Mode | 5–lead (R, L, F, N, C) for leads I, II, III, V, aVR, aVF, aVL |
| ECG Waveform | 3 and 7 channel selectable |
| ECG Gain selection | 0.5mm/mv 1mm/mv 2mm/mv |
| ECG Sweep Speed | 12.5 mm/s 25 mm/s 50 mm/s |
| Heart Rate range | Adult : 15 ~ 300 bpm Neonate /Pediatric : 15 bpm ~ 350 bpm Alarm range : 15 ~ 350 bpm |
| ECG Accuracy | +1 bpm |
| ECG Resolution | 1 bpm |
| Protection | withstands 4000VAC/50 voltage isolation |
| S‐T segment analysis | Range : -2.0 mV ~ +2.0 mV Accuracy: ‐0.8mV ~ +0.8mv Error: +0.02Mv |
| Arrhythmia analysis | |
| Scaling | 1mv, +3% |
| SpO2 Measurement range | 0% ~ 100% Alarm range : 0% ~ 100% |
| SpO2 Accuracy | ±2 % (70 % – 100 %) 0 – 69% unspecified |
| SpO2 Pulse Rate | Range : 20bpm ~ 300bpm Resolution: 1bpm Error: +1bpm |
| NIBP Method | Digital Automatic Oscillometric |
| NIBP Operation Mode | Manual/Automatic/Continuous for Systolic, Diastolic and Mean |
| Auto Measurement | Adjustable Duration : 1 ~ 480 mins |
| Range Of Systolic Pressure | Adult: 40 ~ 270mmHg Pediatric: 40 ~ 220mmHg Neonate: 40 ~ 135 mmHg |
| Range Of Diastolic Pressure | Adult: 10 ~ 215 mmHg Pediatric: 10 ~ 150 mmHg Neonate :10 ~ 100 mmHg |
| Over‐pressure Protection | Double safety protection |
| Respiratory Method | Thoracic impedance |
| Respiratory Measurement range | Adult: 7 ~ 120 rpm Neonate/Pediatric: 7 ~ 150 rpm |
| Apnea Alarm | 10s ~ 40s |
| Respiratory Resolution | 1 rpm |
| Respiratory Accuracy | ±2 bpm |
| Temp Measurement range | 5 ℃ ~ 50 ℃ |
| Average Measuring Time | < 10 sec |
| Temp Resolution | 0.1℃ |
| Temp Accuracy | ± 0.1℃ |
| Display | 12.1’’color TFT |
| Resolution | 800 x 600 dot pixels |
| Trend | 5 s/piece, 8 hours 5min/piece, 1000 hours |
| Alarm | User‐adjustable 3‐level Audio-visual alarm. |
| Safety Standard | Class I, type CF |
| Working Temperature | 0 ~ 40℃ |
| Relative Humidity | ≤ 85 % |
| Power Supply | AC 100 ‐ 240 V, 50/60 Hz |
| Battery | Rechargeable Lead acid cell, 12 V/4 Ah |
| Storage | NIBP : 1000 groups Alarms : 200 groups Holographic waveform : 1 hour |
| Dimension | 280 × 420 × 480 mm |
| Weight | 5 Kgs |